1 User’s Manual Professional Rack Mount UPS PR3000 K01-3000SCA-01
10Circuit Breaker Reset for Overload Protection Re-settable circuit breakers provide optimal overload protection. USB PORT Through USB communicat
11Communication Protection Ports Ethernet RJ-45 Network Protection Ports protect standard network cables. The Primary computer (with PowerPanel P
12Problem Possible Cause Solution Circuit breaker is tripped due to overload. Turn the UPS off and unplug at least one piece of equipment. Wait
13Model PR3000 Capacity(VA) 3000VA Capacity(Watts) 2200W Input Voltage Range 80-150Vac Frequency Range 47-63Hz Output On battery Output Voltage
14 Power On AVR Using Battery Circuit BreakerAlarm Condition On Off Off Set Off Normal On Slow flash Off Set Off AVR- Max. boost 13% of in
15Contact your dealer or call the CyberPower Technical Support in this manual for information on battery replacement. Read and follow the IMPORTAN
16REMINDER: Batteries are considered as HAZARDOUS WASTE and must be disposed of properly. Contact your local government for more information about p
17 By purchasing a CyberPower PR3000 in the United States or Canada, the original end-user(referred to as the “Initial Customer”) receives a Limited
18LIMITED WARRANTY CyberPower warrants to you, the Initial Purchaser, that the Product will be free from defects in material and workmanship for thr
19or e-mail CyberPower at [email protected], within ten (10) days of the event for which you wantto make a claim. 3. When you contact Cy
2TABLE OF CONTENTS SAFETY WARNINGS……………………………………………..3 BLOCK DIAGRAM……………………..…………………………4 INSTALLATION………………..………………………………….4 - UNPACKING………...……………
20which is for the lifetime of the Product),(d) none of the limitations or exclusions on warranty coverage apply (other than the three year limit),
21are available to the Initial Customer and the name of the power utility supplier for the location of the Connected Equipment and Request a Return
222. The aggregate ceiling amount for all Connected Equipment: CyberPower PR3000$200,000.00. 3. The amount(s) of all payment you have or are entitle
23State or Provincial law may adjust the terms of the Limited Warranty or the Connected Equipment Guarantee or the State or Province may impose addi
24Exclusion of Consequential and Other Damages The sole and exclusive remedies of the Initial Customer are those provided by the Limited Warranty a
25Goods is expressly excluded. Contact Information: CyberPower's address is 5555 12th Ave East, Suite 110, Shakopee, MN 55379 and its phone num
3 z This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the
4UNPACKING Inspect the UPS upon receipt. The box of PR3000 should contain the following:(1) UPS Unit; (1) User’s Manual; (2) Rack Mount Brackets;
5TO ESTIMATE POWER REQUIREMENTS: 1. ______Watts (W) x 2.0 = _____VA or _____Amps (A) x 120 =____VA 2. Add the totals up for all pieces of equipment
66. Depress the power switch to turn the unit on. The power on indicator light will illuminate. 7. Your UPS is equipped with an auto-charge feature
7Figure 1: Connecting PR3000 with Battery Pack
8FRONT PANEL DESCRIPTION Power Switch Press the power button to turn the UPS ON or OFF Test SwitchThe PR-UPS performs a self-test automatica
9Load Level Indicators This indicator shows a visual depiction of the UPS load. The load indicator LED will turn orange if the load is between 80 a