causes to search the network to update the results. This option appears when power connection is set from
computer to network PDU directly.
ATS Address: This option appears when the power of a computer is configured to connect to an ATS.
PDU Name: Selects the target generic PDU from list. After the UPS with Generic PDU of the Power Connection
option is selected and entering a UPS address, the computer will fetch the list of installed PDU from UPS. If the list
is empty, then you have to install the PDU in UPS/Load page of PowerPanel Business Edition Agent. This option
appears when power connection is set from the computer to a PDU that is an extension power of the UPS, which
is controlled by PowerPanel Business Edition Agent.
UPS Outlet, PDU Outlet and ATS Outlet: Indicates which power outlet of the UPS or PDU/ATS is supplying
power to the computer that has been installed PowerPanel Business Edition Client software. The outlet list will be
updated after entering a network address of UPS or PDU/ATS. Outlet preview will be shown with a selected outlet
accordingly for assisting to verify whether the computer is connected to the proper outlet.
The Identify button is only visible after the Client has established communication with the network PDU; the
identification function helps to identify which outlet has the connected equipment. The PDU will blink the outlet
number on the LCD screen to verify the actual connection on the PDU matches when the Identify button is
pressed.
How to Configure Proper Power Connection
In order to identify the difference between the power connections, the proper power connection should be chosen
accordingly:
If Client only connects with single UPS or single PDU, the Power Connection should be set UPS or PDU. Enter
the required IP address and assign the correct outlet. Click OK to establish communication. Note: The UPS
must be installed a standalone RMCARD or controlled by a computer which has been installed the Agent; the
PDU must have the network function.
If Client connects with a network PDU that is a power extension from the UPS, the Power Connection should
be set UPS with network PDU. Enter the IP address of UPS. Enter the IP address of PDU and assign the
correct PDU outlet. Click OK to establish the communication.
If Client connects with a generic PDU that is a power extension from the UPS, the Power Connection should
be set UPS with generic PDU. Enter the IP address of UPS, choose the according PDU model and assign the
correct PDU outlet. Click OK to establish the communication. Note: A generic PDU is a PDU that have no
network function.
If Client connects with an ATS, the Power Connection should be set ATS first. Enter the IP address of ATS and
assign the outlet. Users should know whether ATS is being supplying power by any UPS to realize how to
configure the detail:
If the ATS is a power extension from the two UPS, enter the IP address of UPS individually. Click OK to
establish the communication.